UPower-Hi series is an inverter charger that supports diversified energy management modes on solar/utility/genera- tor charging,and utility/inverter power supply to the AC loads. To maximize solar energy utilization, users can choose energy sources accordingto actual needs and flexibly take the utility as a supplement. This inverter charger can raise the system's power supply guarantee rate, which is suitable for solar energy, utility/oil generator hybrid systems. It aims to provide users with high-quality, high-stability, and high-reliability electrical energy.
Item | UP2000-HM6021 | UP3000-HM5041 | UP2000-HM6022 | UP3000-HM5042 | UP3000-HM10022 | UP5000-HM8042 |
Nominal battery voltage | 24VDC | 48VDC | 24VDC | 48VDC | 24VDC | 48VDC |
Battery input voltage | 21.6~32VDC | 43.2~64VDC | 21.6~32VDC | 43.2~64VDC | 21.6~32VDC | 43.2~64VDC |
Max. battery charging current | 60A | 50A | 60A | 50A | 100A | 80A |
Inverter output | ||||||
Continuous output power | 2000W | 3000W | 2000W | 3000W | 3000W | 5000W |
Max. surge power | 4000W | 6000W | 4000W | 6000W | 6000W | 8000W |
Output voltage range | 110VAC(-3%~+3%); 120VAC(-10%~+3%) |
110VAC(-3%~+3%); 120VAC(-10%~+3%) |
220VAC(-6%~+3%); 230VAC(-10%~+3%) |
220VAC(-6%~+3%); 230VAC(-10%~+3%) |
220VAC(-6%~+3%); 230VAC(-10%~+3%) |
220VAC(-6%~+3%); 230VAC(-10%~+3%) |
Output frequency range | 50/60Hz±0.2% | |||||
Output wave | Pure sine wave | |||||
Load power factor | 0.2-1(Load VA ≤ Continuous output power) | |||||
Distortion THD | THD≤5% (Resistive load) |
THD≤5% (Resistive load) |
THD≤3% (Resistive load) |
THD≤3% (Resistive load) |
THD≤3% (Resistive load) |
THD≤3% (Resistive load) |
80% rated output efficiency | 89% | 91% | 92% | 92% | 92% | 92% |
Max. rated output efficiency | 88% | 90% | 91% | 90% | 91% | 91% |
Max. output efficiency | 90% | 92% | 93% | 93% | 93% | 93% |
Utility charging | ||||||
Utility input voltage | 88VAC~132VAC(Default); 80VAC~140VAC (Programmable) |
88VAC~132VAC(Default); 80VAC~140VAC (Programmable) |
176VAC~264VAC(Default); 90VAC~280VAC (Programmable) |
176VAC~264VAC(Default); 90VAC~280VAC (Programmable) |
176VAC~264VAC(Default); 90VAC~280VAC (Programmable) |
176VAC~264VAC(Default); 90VAC~280VAC (Programmable) |
Utility input frequency | 40~65Hz | |||||
Max. utility charge current | 60A | 40A | 60A | 40A | 80A | 60A |
Solar charging | ||||||
Max. PV open circuit voltage | 250V(At minimum temperature); 220V(25ºC) | 250V(At minimum temperature); 220V(25ºC) | 450V(At minimum temperature); 395V(25ºC) | 450V(At minimum temperature); 395V(25ºC) | 450V(At minimum temperature); 395V(25ºC) | 500V(At minimum temperature); 440V(25ºC) |
MPPT voltage range | 60~200V | 60~200V | 80~350V | 80~350V | 80~350V | 120~400V |
Max. PV input power | 2000W | 3000W | 2500W | 4000W | 4000W | 4000W |
Max. PV charging power | 1725W | 2875W | 1725W | 2875W | 2875W | 4000W |
Max. PV charging current | 60A | 50A | 60A | 50A | 100A | 80A |
Equalize charging voltage | 29.2V(AGM default) | 58.4V(AGM default) | 29.2V(AGM default) | 58.4V(AGM default) | 29.2V(AGM default) | 58.4V(AGM default) |
Boost charging voltage | 28.8V(AGM default) | 57.6V(AGM default) | 28.8V(AGM default) | 57.6V(AGM default) | 28.8V(AGM default) | 57.6V(AGM default) |
Float charging voltage | 27.6V(AGM default) | 55.2V(AGM default) | 27.6V(AGM default) | 55.2V(AGM default) | 27.6V(AGM default) | 55.2V(AGM default) |
Low voltage disconnect voltage | 21.6V(AGM default) | 43.2V(AGM default) | 21.6V(AGM default) | 43.2V(AGM default) | 21.6V(AGM default) | 43.2V(AGM default) |
Tracking efficiency | ≥99.5% | |||||
Temperature compensate coefficient | -3mV/ºC/2V (Default) | |||||
General | ||||||
Surge current | 50A | 56A | 50A | 56A | 60A | 95A |
Zero load consumption |
<1.6A | <1.2A | <1.8A | <1.2A | <1.8A | <1.2A |
(without PV and utility connection, turn on the load output) | ||||||
Standby current |
<1.2A | <0.7A | <1.2A | <0.7A | <1.2A | <0.7A |
(without PV and utility connection, turn off the load output) | ||||||
Dimension(HxWxD) | 607.5x381.6x127mm | 642.5x381.6x149mm | 607.5x381.6x127mm | 607.5x381.6x149mm | 642.5x381.6x149mm | 642.5x381.6x149mm |
Net Weight | 15kg | 19kg | 15kg | 18kg | 19kg | 19kg |
Operating temperature range | `-20ºC~50ºC (derating above 30ºC ) | |||||
Relative humidity | < 95%(N.C.) | |||||
Enclosure | IP30 |
With over 10 years development, For Leaves Ltd, now focus on the design and manufacturing of HIGH QUALITY custom solar panels and solar applications.
Offer professional design and choose more proper materials to match customer's requirements.
Product covers the traditional standard glass panel and custom solar panels, as well the related solar applications & solar components.
Provide comprehensive service for customers, satisfy different customer's demands.
Save Customer's development time and cost.
Product Range:
Standard Glass Panel upto 540W
ETFE/ PET Flexible Solar Panel
ETFE/ PET Foldable Solar Panel Charger
Epoxy Solar Panel
MINI Glass Solar Panel
Solar Street Light
Solar Flood Light
Solar Cables and Connectors
Solar Pump Inverter
Solar Charge Controller and Inverter
Lithium Battery Pack
Solar Structure
......